Littelfuse SymCom 520CP-230 MotorSaver.

520CP-115_1.jpg
Picture is for reference only.

Part Number:

MS520CP230

Manufacturer:

SymCom Obsolete

Manufacturer Part Number:

520CP-230
Littelfuse SymCom 520CP-230 MotorSaver is a fully programmable, microcontroller-based, current sensing device designed to monitor 3-phase pumps or systems with ramp up times of 4 seconds or less.

Item Discontinued

Click below to request an agent review potential options.

Weight:

10 lbs

Dimensions:

6 x 11 x 8 inches

HS Code:

8535.90.4000

Technical Details

Product Family:

MotorSaver

Model Type:

520

Input Power:

DNU5

Input Phase:

3

Input Hz:

60/50

Current Monitoring:

Fixed

Undercurrent Trip:

0.00 to OC trip point

Overcurrent Trip:

UC trip point to 5 Amps

Phase Monitoring:

Single Phasing, Reverse Phasing

Restart Delay:

On power up: 0-500s; after all faults: 2-500m

Littelfuse SymCom 520CP-230 MotorSaver is a fully programmable, microcontroller-based, current sensing device designed to monitor 3-phase pumps or systems with ramp up times of up to 50 seconds. Applications include submersible pumps, booster pumps, reverse osmosis systems, centrifugal pumps, vertical turbine pumps, oil well pumps, chemical pumps or other similar systems.

520CP Protects Motors From:
• Overload or jammed impeller
• Underload or dry well
• Current unbalance
• Current single phase
• Reverse phase
• Rapid cycling 

Features:
• 3-digit LED diagnostic display
• Last fault diagnostics
• Automatic or manual reset
• Remote reset capability

Three external current transformers must be utilized in conjunction with the Model 520CP. The following 9 set points can be set and viewed from the 3-digit alphanumeric LED: overcurrent trip point, undercurrent trip point, current unbalance trip point, trip delay, rapid cycle timer (RD1), overload restart delay (RD2), underload restart delay (RD3), number of restarts after an overload, and number of restarts after an underload fault. Last fault diagnostics is also viewable. When a harmful condition is detected, the 520CP’s output relay is deactivated after the specified trip delay. The output relay reactivates after the appropriate RD2 or RD3 timer has expired. If the pump is started on a single-phase or a reverse-phase condition, the Model 520CP deactivates its output relay in 0.5 seconds.

Disclaimer Notice: Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.